友情提示:本型号产品不含熔断器(熔芯),请您根据自己(客户)的现场要求,找专业技术人员准确选型后使用。
郑重说明:以上提供的宝贝照片为厂家*新标识的产品,即在蓝色透明罩上新标识与老标识有所不同,其他方面无变化。新标识为QCB NH, 老标识为LTS。老标识的产品大约在6-7年前停用,不再销售,新标识产品在纸盒(箱)外包装上,和开关内部(装熔芯处)还是印有LTS标识。如有异议,请以官方(厂家)的**型号(订货号)为准。
DescriptionPart No.: 33603
QUADRON174;CrossLinkBreaker
NH bus-mounting fuse switch disconnector size 3, 630 A
3-pole, 60 mm system, outgoing terminals at bottom / top,
for busbars 12, 15, 20, 25, 30 x 10 double-T- and triple-T-sectionSystem60mm-System classicProduct AdvantagesDisconnectors are equipped with arc chambers.
The shock protection cover is in 2 pieces to provide for safe connection of cables.
The lid is provided with self-closing inspection holes.Product Group Subgroup9
33StandardsIEC 60947-1:2004
IEC 60947-3:1999
IEC 60947-1:2007
IEC 60947-3:2008
EN 60947-1:2007
EN 60947-3:2009
DIN EN 60947-1/04.08
DIN EN 60947-3/02.10ApprovalsIEC (CB), Niederlande, Germanischer Lloyd, GOST, CCC
Type No.: LTS3
CCC certificate: 2004010302117263Electrical Data690 V AC / 630 A
rated insulation voltage 800 V
rated surge withstand capacity 6 kV
conditional rated short circuit current 50 kA (with fuse links gL/gG)
switching capacity / application categories AC23 B (400 V),
AC22 B (690 V), AC21 B (690 V), DC22 B (440V), DC21 B (440 V),
for fuse links to IEC 60269-2-1 (I) / DIN VDE 0636-201 size 1 up to 48 W
AC20B (1000 V), DC20B (1000 V) pollution degree 2
visible instruction necessary; if application more than DC 440V /AC 690V:
do not operate under load
DC specifications: 2 current paths (L1, L3) in series.
According to the AC and DC switching characteristics and in consideration of the overload conditions, the following distances to earth metal parts have to be provided.
- top 300mm, side 130mm
By using as a disconnector (switching not under load) the mentioned distances are not applicable.
Power dissipation:
The power dissipation of the device results in 38,4 W at a typical
load with 80 % of the nominal current.
(The power dissipation is 60 W for application at nominal current.)
Degree of protection IP30 (front side), degree of protection near terminal depends on installation.Mechanical DataWidth x Height x Depth (mm): 256 x 300 x 160
Weight (kg/100): 756
patented locking mechanismConnectionsAccessories:
Clamp: Cu 150-300 mm2 rm, f+AE; la. Cu 25x1-13; 6-8 Nm tightening torque
Wedge clamp (single): Cu, Al* 50-150 mm2 6-8 Nm tightening torque
Wedge clamp (double): Cu, Al* 2x150/185 mm2 rm,sm, f+AE; 6-8 Nm tightening torque
* not maintenance-free when aluminium conductors are used
screw M12 :
Md 35 - 40 NmMaterial CharacteristicsMain body:
temperature stability 150°C,
self-extinguishing in acc. to UL 94
halogen-free
Shock protection cover:
temperature stability 125°C,
self-extinguishing in acc. to UL 94,
creepage resistance CTI 200,
Handle:
temperature stability 125°C,
self-extinguishing in acc. to UL 94,
creepage resistance CTI 200,
halogen-free
Contacts:
spring-loaded contacts,
copper, silver plated
Connecting screws:
hexagon head cap screw M12
wrench size 18
galvanized, chromized
Adapter plate:
temperature stability 150°C,
self-extinguishing in acc. to UL 94
halogen-freeVersionsSee 33 325 for variant with fuse monitoring.
See 33 162 for variant with electromechanically fuse monitoring.Pack Size1