适用范围 Scope of application
交流电源防雷模块适用于配电室、配电柜、开关柜、交直流配电屏等系统的电源保护,建筑物内有室外输入的配电箱、建筑物层配电箱,用于低压( 220/380VAC)工业电网和民用电网,在电力系统中, 主要用于自动化机房、变电站主控制室电源屏内三相电源输入或输出端。
AC power supply lightning protection module is suitable for the power supply protection of power distribution room, power distribution cabinet, switch cabinet, AC for DC power distribution panel system; the building has the distribution box input from outdoor and building floor distribution box, use for low voltage (220/380VAC) industrial power grid and civil power; in the power system, it is mainly used for three-phase power input or output of the power supply panel of the automatic engine room, main control room of substation.
型号及含义 Model and implication
M M 80 A 320 BC —— T按客户要求特制产品的标识
Customized products according to customer requirements
B+C(I+II)复合型防雷
B+C (I+II) composite type lightning protection
*大持续工作电压,如为385V则不标
4Maximum continuous operating voltage, as 385V is not indicated
保护方式代码 Protected mode code
*大放电电流,单位为
KA The maximum discharge current, the unit is KA
模块式电源防雷器代号
Module type power supply lightning protection device code
企业代号 Enterprise code
主要技术参数 Main technical parameters型号ModelAMM100AAMM80BAMM60CAMM40D标称工作电压Un
Nominal operating voltage Un220V*大持续工作电压Uc
Maximum continuous operating voltage Uc320V/385V标称放电电流
In ( 8/20μs)
Nominal discharge current
In ( 8/20μs)50kA40kA30kA20kA*大放电电流
Imax (8/20μs)
Maximum discharge current
Imax (8/20μs)100kA80kA60kA40kA保护模式
Protection modeL1,L2,L3,N-PEL1,L2,L3,-N
N-PEL,N-PEL-N
N-PE保护水平Up
(8/20μs In)
Protection level Up
(8/20μs In)2000V180015001500响应时间
Response time≤25ns外形尺寸
Outline dimension90*145*6390*145*6390*36*6990*36*69接线线径
Wiring route25mm225mm216mm210mm2防护等级
Protection levelIP20安装方式
Installation method35mm导轨安装
35mm Guide rail installation工作环境
Working environment环境温度:-40℃~+85℃; 相对湿度:≤95%(25℃);海拔≤3km
Ambient temperature: -40℃~+85℃; relative humidity: ≤95%(25℃); altitude≤3km;
订货须知 Ordering instructions
订货时必须指出:名称及产品型号规格、数量
例如:AMM 80A 50台
The following must be pointed out when an order is placed: Name and product model specifications, quantity
For example: 80A AMM 50 units